Auxiliary Hardware

Prodotti

Modules

OA1-M

Lynx Analog Output Module  - Shielded

This isolated, analog output module can be used to interface with any sensor, or input, that accepts a 0-10V DC signal, like plastic and hydraulic pressure input cards. It can also be used as an external machine transfer.

Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and the eDART® System. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-D to terminate the DIN rail module chain.

Features and benefits:

  • Easier installation and troubleshooting
  • Increased immunity to interference in electronically noisy environments
  • Convenient 35 mm DIN rail mounting
  • Removable/replaceable cables

Download

Manuale prodotto
OR2-M

Lynx Dual Relay Output Module  - Shielded

The dual contact closure output module is designed to be used with the eDART® System. The module's two dry contact outputs can also be configured to implement part containment or transfer a molding machine.

Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules as well as the eDART System. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-D to terminate the DIN rail module chain. 

Features and benefits:

  • Easier installation and troubleshooting
  • Increased immunity to interference in electronically noisy environments
  • Convenient 35 mm DIN rail mounting
  • Easy-to-read status LEDs
  • Removable/replaceable cables

Download

Manuale prodotto
IA1-M-V

Lynx Analog Input Module - Shielded

This module accepts 0-10V DC signals from analog sensors and equipment in order to integrate them into the eDART® System. This din-rail module is shielded to ensure high quality data even in rugged molding environments. Examples of sensors that can be used with this module include: electric machine injection pressure, temperature, dew point, and plastic pressure.

Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and the eDART System. Each machine panel installation of one or more DIN rail module requires either an ID7-M-SEQ or a DIN/LX-D to terminate the DIN rail module chain.

Features and benefits:

  • Easier installation and troubleshooting
  • Increased immunity to interference in electronically noisy environments
  • Convenient 35 mm DIN rail mounting
  • Removable/replaceable cables

Download

Manuale prodotto
IA2-M-FT

Lynx Flow-Temperature Sensor Interface  - Shielded

The IA2-M-FT Lynx Flow-Temperature Interface Module provides all the inputs and outputs needed to interface the eDART® System to Smartflow®’s TracerVM™ line of flowmeters. This din-rail module is shielded to ensure high quality data even in rugged molding environments.

Download

Manuale prodotto
ID7-M-SEQ

Lynx Sequence Module  - Shielded

Once wired to the molding machine, this module provides the system with machine timing sequences, including injection forward, screw run, mold closed, first stage, and mold opening. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. .

Features and benefits:

  • Easier installation and troubleshooting
  • Increased immunity in eletrically noisy environments
  • Convenient 35 mm DIN rail mounting
  • Easy-to-read status LEDs
  • Removable/replaceable cables

Download

Manuale prodotto
DIN/LX-M

Lynx Communication Adapter  - Shielded

The DIN/LX-M is a Lynx to DIN rail communications module that acts as an interface between standard Lynx cables and Lynx DIN rail mounted modules when not using an ID7-D-SEQ. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. It is designed to be used with the eDART® System and to be mounted on standard 35 mm DIN rails often found in machine panels.

Download

Manuale prodotto
OA1-S-V

MODULO DI USCITA SEQUENZA A MONTAGGIO SUPERFICIALE

Questi possono essere montati ovunque necessario, ed anche dentro o fuori la macchina per stampaggio o all'interno di apparati ausiliari. Il modulo Input analogico, interfaccia con temperatura, punto di rugiada e altri sensori remoti. Il Modulo Uscita Doppio Relè fornisce segnali ai deviatori dei pezzi, ai controllori degli ugelli a valvola, alle schede di input della macchina e ad altre applicazioni.

Download

Manuale prodotto
OR2-S

MODULO DOPPIO RELE MONTAGGIO SUPERFICIE

Questi possono essere montati ovunque necessario, ed anche dentro o fuori la macchina per stampaggio o all'interno di apparati ausiliari. Il modulo Input analogico, interfaccia con temperatura, punto di rugiada e altri sensori remoti. Il Modulo Uscita Doppio Relè fornisce segnali ai deviatori dei pezzi, ai controllori degli ugelli a valvola, alle schede di input della macchina e ad altre applicazioni.

Download

Manuale prodotto
IA1-S-VI-24

MODULO DI INGRESSO SEQUENZA A MONTAGGIO SUPERFICIALE

Questi possono essere montati ovunque necessario, ed anche dentro o fuori la macchina per stampaggio o all'interno di apparati ausiliari. Il modulo Input analogico, interfaccia con temperatura, punto di rugiada e altri sensori remoti. Il Modulo Uscita Doppio Tele fornisce segnali ai deviatori dei pezzi, ai controllori degli ugelli a valvola, alle schede di input della macchina e ad altre applicazioni.

Download

Manuale prodotto
ID7-S-SEQ

MODULO DI SEQUENZA MONTAGGIO SUPERFICIE

Questi possono essere montati ovunque necessario, ed anche dentro o fuori la macchina per stampaggio o all'interno di apparati ausiliari. Il modulo Input analogico, interfaccia con temperatura, punto di rugiada e altri sensori remoti. Il Modulo Uscita Doppio Tele fornisce segnali ai deviatori dei pezzi, ai controllori degli ugelli a valvola, alle schede di input della macchina e ad altre applicazioni.

Download

Manuale prodotto
ID/LX1-S

IDENTIFICATORE STAMPO LYNX

Download

Manuale prodotto
VM-4-B-40-B

Smartflow 1/2" NPT 2-40 LPM

This device is a simple flow meter to measure either the total input to the mold or to individual circuits. This can also be done with water temperature. When interfaced with the eDART® System, users can access and use data such as: excessive reject control, summary variables, template values, and summary and cycle values.

What you can do:

  • Determine if the water temperature control unit is delivering the correct temperature needed to make good parts
  • Reject parts if the flow or temperature doesn't meet your set requirements to make a good part
  • Create a template of the flow or water temperature
  • Overlay your GPM or temperature curves on the cycle graph
  • Set alarms around peak values of the flow or temperature of the coolant
  • Set excessive rejects to stop the machine if the flow or temperature of the coolant rejects parts more than your set thresholds

Junctions

J-LX1

ALIMENTATORE SINGOLO LYNX

Download

Manuale prodotto
J-LX2-CE

GIUNZIONE DUE PORTE CE

Download

Spec Sheet
J-LX5-CE

SCATOLA DI CONNESSIONE STAMPO/PIANO DI PRESSA CE

J-LX9-CE

SCATOLA DI CONNESSIONE STAMPO/PIANO DI PRESSA CE

C-LX-SR-2M-M90 Slip Ring Connector

RJG’s Slip Ring Connectors allow molders with rotary table machines to install digital Lynx cavity pressure sensors without the common cabling impediment of rotational movement. Mounted directly to the rotary table, the slip ring allows for 360° rotation of the table while keeping cabling from becoming entwined. The RJG Lynx slip ring connectors allow eDART® System users to continuously receive information from up to 32 Lynx sensors mounted on rotary table molds.

Adapters

SG/LX1-S

ADATTATORE SENSORE MONTAGGIO SUPERFICIE

Questi adattatori per sensori permettono di collegare a eDART dei sensori piezoelettrici ed estensimetri standard.

Download

Manuale prodotto
LP/LX1-M

ADATTATRE PIEZO MONTAGGIO STAMPO

Questi adattatori per sensori permettono di collegare a eDART sensori piezoelettrici e estensimetri standard.

PZ/LX1-S

ADATTATORE PIEZO MONTAGGIO SUPERFICIE

Questi adattatori per sensori permettono di collegare a eDART sensori piezoelettrici e estensimetri standard.

Download

Manuale prodotto

Machine Interface Sensors

LS-H-1/4NPT-3K

Sensore idraulico Lynx™ 3000# :
L'eDART calcola la pressione di iniezione e la disegna unitamente ad altri profili. Queste curve indicano molte variabili della macchina e del processo, con visualizzazione della consistenza e ripetibilità nel tempo.

 

Download

Manuale prodotto
LE-R-50

Sensore di corsa/velocità LE-R-50"

Il controllo della velocità di iniezione, volume della stampata, cuscino e tassi di plasticizzazione diventano semplici e richiedono solo il collegamento del sensore di corsa e velocità. Il sensore di corsa e velocità è disponibile con cavi di lunghezze varie per essere usato su macchine di diverse dimensioni.

Download

Manuale prodotto
L-PX

INTERFACCIA INTERRUTTORE DI PROSSIMITÀ LYNX

Download

Manuale prodotto
Sensore di pressione ugello

- Interfaccia con Dynisco PT4676-30M-10/18

Download

Manuale prodotto
Flussometro Elettronico TRACER®

Misura la portata del liquido, la sua temperatura, calcola BTU al minuto, e flusso turbolento. Il display è chiaramente visibile tramite il pulsante e menù molto semplice.

Gli utenti eDART possono interfacciare con il sistema eDART con i due moduli di ingresso digitali. Uno per la portata d'acqua e uno per la temperatura dell'acqua.

Per ulteriori informazioni, visitare il sito di Smartflow

SUMI-LX

SCATOLA INTERFACCIA SUMITOMO

Download

Manuale prodotto
LT3-L

LYNX INDICATOR LIGHT TREE

The LT3‑L is a molding machine mountable indicator light tree designed to be used with the eDART® system.

The light tree works with the eDART software to visually indicate if your process is running within limits.

Download

Manuale prodotto
Tester ID7

Il tester ID7 applica corrente ai moduli ID7-D-SEQ. Questo permette all'installatore di controllare il cablaggio corretto del circuito senza collegare il ID7-D-SEQ a un eDART™.

Download

Manuale prodotto

Discontinued

LE-R-30

Sensore di corsa e velocità LYNX 30":
Controllo della velocità di iniezione, volume della stampata, cuscino e tassi di plasticizzazione diventa semplice e richiede solo il collegamento del sensore di corsa e velocità. Il sensore di corsa e velocità è disponibile con cavi di lunghezze varie per essere usato su macchine di diverse dimensioni.

Download

Manuale prodotto
LS-DP-100

Sensore di flusso acqua Lynx :
Il sensore misura la differenza di pressione tra l'entrata e l'uscita dello stampo ed è progettato per essere usato con il sistema eDART™. Fornisce informazioni sulla capacità e consistenza di raffreddamento fornita alla parte stampata.

Download

Manuale prodotto
LS-TESTER

TESTED SENSORE LYNX

Download

Manuale prodotto
SG/LX8-S-ID (Old Version)

Lynx 8 Channel Strain Gage Adapter with ID

The Lynx 8 Channel Strain Gage Adapter provides strain gage cavity pressure sensor users with a convenient, simple interface to multi-channel strain gage systems.

Download

Manuale prodotto
OA1-D-V

MODULO OUT ANALOGICO 0-10V LYNX

Download

Manuale prodotto
OR2-D

MODULO USCITA DOPPIO RELE

Per quelle macchine e apparecchiature automatizzate che accettano segnali digitali, questo dispositivo fornisce un contatto normalmente chiuso o normalmente aperto per il controllo del processo o la selezione di pezzi 3-Way.

Download

Manuale prodotto
ID7-D-SEQ

MODULO DI SEQUENZA 7 INGRESSI LYNX

Dopo aver collegato la macchina questo modulo fornisce al sistema con le sequenze compreso fase iniezione, rotazione vite, stampo chiuso, primo stadio e stampo aperto.

Download

Manuale prodotto
IA1-D-VI

MODULO INPUT ANALOGICO 0-10V LYNX

I sensori analogici possono essere integrati con il Sistema eDART™. Questo modulo accetta un segnale da 0-10 VCC da questi dispositivi e lo trasmette al eDART.

Download

Manuale prodotto
DIN/LX-D

ADATTATORE COMUNICAZIONI LYNX

Il Lynx / DIN è un modulo di comunicazione Lynx su binario DIN che opera come interfaccia tra i cavi standard Lynx e i moduli Lynx montati su binari DIN quando non si usa un ID7-D-SEQ.

Download

Manuale prodotto
LT3-1/2-120

SEMAFORO INDICATORE LYNX