<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>v10 - eDART System Software | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-category/scaricamento-software/v10-edart-system-software/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Tue, 05 Sep 2023 12:27:08 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://it.rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>v10 - eDART System Software | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>eDART Software Version: 10.8.5</title>
		<link>https://it.rjginc.com/product/edart-software-version-10-8-5/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 05 Sep 2023 12:26:50 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=260054</guid>

					<description><![CDATA[This document covers only the series v10 releases. September, 2023 What&#8217;s New in Release &#8216;10.8.5&#8217; Bug Fixes Fixed an issue with SG/LX and PZ/LX adapters >20******** [2020-year date], where a user could assign the sensors but would not be able to add them on the Cycle Graph, nor be able to review them on the [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>This document covers only the series v10 releases. </p>
<p><i>September, 2023</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.5&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an issue with SG/LX and PZ/LX adapters >20******** [2020-year date], where a user could assign the sensors but would not be able to add them on the Cycle Graph, nor be able to review them on the Raw Data Viewer.</li>
<li>Fixed an issue with ID7 and OR2 modules >20******** [2020-year date], where the user may be able to assign the modules; however, Raw Data Viewer would report incorrect values for the modules.</li>
</ul>
<p><i>February 24, 2022</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.4&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an assignment issue with multichannel strain gage adapters (MCSG), where, if a user added then removed a sensor, it<br />
      could potentially cause the system to lock up before a reboot.</li>
</ul>
<p><i>August 3, 2021</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an issue with the Raw Data Viewer’s Port Diagnostics reporting negative values on devices which contained a serial<br />
      number greater than 20******** [2020-year date].</li>
</ul>
<p><i>June 10, 2021</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.2&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Improved performance when selecting a Machine, Mold or Setup when there are a large number of configurations in the pick list.</li>
</ul>
<p><i>June 14, 2017</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be<br />
      interrupted.  When system restored communication, some sensors would be missing.</li>
</ul>
<p><a name="_Hlk485215776"><i>February 23, 2017</i></a></p>
<h2><a name="_Hlk485215738">What&#8217;s New in Release &#8216;10.8&#8217;</a></h2>
<h3><a name="_Hlk485215806">Bug<br />
    Fixes</a></h3>
<ul>
<li>Support for new 4 Channel Piezo adapters</li>
<li> Support for The Hub integration, still requires<br />
      patch to enable</li>
</ul>
<p><i>November 16, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Support for 6mm Strain Gage sensors </li>
<li>Fixed bug where initial offset was always be set to zero on strain gage sensors </li>
</ul>
<p><i>October 10, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Can assign IA1 modules on Machine setup for coolant flow and temperature </li>
<li>When overwriting template in cycle graph the dialog would not close automatically </li>
<li>Audit log was no longer updating because the log file name was changed </li>
<li>Various translation fixes </li>
</ul>
<p><i>September 2, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>The Balance Viewer in the Cycle Graph did not show any data in other languages </li>
<li>You can now see the date that a template was saved when selecting a template in the Cycle Graph </li>
</ul>
<p><i>August 1, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<ul>
<li>A user can now assign multiple flow meters in the machine setup and input an id for each sensor </li>
</ul>
<p><i>July 1, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed &#8216;Process Setup&#8217; disappearance issue. </li>
</ul>
<p><i>June 6, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed regression of not being able to assign multi channel piezo adapters with missing plate id </li>
<li>Fixed bug with V-&gt;P where changes would be reverted if you changed a value by more than 10% </li>
<li>Fixed bug where if you started a job with an unassigned sensor it would have incorrect default values set when you<br />
      configured it later </li>
<li>Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries </li>
<li>It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still<br />
      path to get both to show </li>
<li>Fixed bug with analog inputs where if they are converted from v9 setup they would have a full scale of 0 </li>
</ul>
<p><i>Apr 11, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Set Screw Bottom is no longer skipped when<br />
      starting a job after a reboot </li>
<li>Fixed the Job Started Output so that the module<br />
      channel activates when a job is started </li>
<li>Removed the annotator and replaced it with a<br />
      cycle values display on the cycle graph </li>
<li>Cavity Fill Time Balance Percentage added as a<br />
      summary variable. </li>
<li>Cushion can be calculated with analog input<br />
      modules </li>
<li>V-P layout improved for better visibility of the<br />
      cycle graph window </li>
<li>Mini Mega MCSG Adapter Support </li>
<li>i icon missing for<br />
      Sensors setup </li>
<li>Analog input sensors used for stroke now allow 0<br />
      and 10 V to be swapped between screw bottom and full shot </li>
<li>Balance Viewer Sensor Name display as cavity<br />
      names instead of aliases </li>
<li>Corrupt file and directory detection and handing </li>
</ul>
<p><i>Dec 3, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of<br />
      temperature </li>
<li>Fixed bug introduced in 10.7.1 that would not<br />
      show sensors on the Mold Outputs configuration page </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug where you could assign MCSG sensor<br />
      when a plate was not attached which would cause sensor location to block when<br />
      starting a job </li>
<li>Fixed bug where sensors would not correctly<br />
      populate the unused sensor list </li>
<li>Fixed bug where mega multi<br />
      channel sensor may not show up as connected if connected after you start<br />
      editing the mold </li>
<li>Changed the way the Multi channel adapter<br />
      display the plate that is attached, it now shows both the adapter serial number<br />
      and plate id, when a sensor is configured in a location is only shows the plate<br />
      id </li>
<li>Fixed that you could not show summary variables<br />
      or add alarms for Coolant Flow Temperature sensors </li>
<li>Added support for new mega SG/LX8-S-ID </li>
</ul>
<p><i>Aug 6, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Cycle Graph pop-up annotator replaced by fixed<br />
      location cycle values and balance viewer. </li>
<li>Excessive Rejects clear function now has it&#8217;s own security item called &quot;Excessive Rejects&quot;; was previously bundled in with the process security. </li>
</ul>
<p><i>July 8, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable </li>
<li>Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access </li>
<li>Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing </li>
<li>On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed </li>
<li>On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works </li>
<li>On the cycle graph, template control windows should open in consistent positions </li>
<li>Long text should no longer be cutoff on the Alarm Settings page </li>
<li>Long text should no longer be cutoff on the Stability Match pages </li>
<li>Long text should no longer be cutoff on the Cycle Alarm indicators </li>
<li>Long text should no longer be cutoff on the Alarm Count page </li>
<li>Values on Cycle Alarm indicators are now displayed in current units and the units are shown </li>
<li>On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the mold setup. This would lead to sensors not being configured correctly if the<br />
      setup was then saved. It will now have the right settings. </li>
<li>When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was<br />
      confusing. It no longer does this. </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and<br />
    Changes</h3>
<ul>
<li>Support for Peak Ejector Force Optional Tool. </li>
<li>Added support for dual analog flow/temperature IA2-M-FT. </li>
</ul>
<h3>Bug Fixes</h3>
<ul>
<li>Fix for Valve Gate always defaulting to &quot;Open Gate&quot;. </li>
<li>Fix for job started output, now on when the job<br />
      is running and off when the job is started. </li>
<li>Template Match Values are now displayed. </li>
<li>Home menu now disappears when focus is lost. </li>
<li>Disallows testing Job Started, Job Down and Job Running outputs while the job is running. </li>
</ul></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>eDART Software Version: 10.8.4</title>
		<link>https://it.rjginc.com/product/edart-software-version-10-8-4/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 08 Mar 2022 20:05:27 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=238144</guid>

					<description><![CDATA[<div class="modal-header">
<h3 id="note-modal-title">Important Note</h3>
</div>
<div class="modal-body">
<div id="note-content">

The <em>eDART</em> must be at 10.7 or above before this update can be applied.

The EDM Upgrade 2.6.1 is REQUIRED in order for the <em>eDART</em>s to share security files and default files automatically. Please read how the new automatic copy will work with this upgrade. <a href="https://rjginc.com/wp-content/uploads/2018/10/File_Version_Control.pdf">The attached file is the read me file.</a>

</div>
</div>]]></description>
										<content:encoded><![CDATA[<div>
<p>This document covers only the series v10 releases.</p>
<p style="text-align: right;" align="right"><i>February 24, 2022</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.4&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed an assignment issue with multichannel strain gage adapters (MCSG), where, if a user added then removed a sensor, it could potentially cause the system to lock up before a reboot.</p>
<p style="text-align: right;" align="right"><i>August 3, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed an issue with the Raw Data Viewer’s Port Diagnostics reporting negative values on devices which contained a serial number greater than 20******** [2020-year date].</p>
<p style="text-align: right;" align="right"><i>June 10, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Improved performance when selecting a Machine, Mold or Setup when there are a large number of configurations in the pick list.</p>
<p style="text-align: right;" align="right"><i>June 14, 2017</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be interrupted. When system restored communication, some sensors would be missing.</p>
<p style="text-align: right;" align="right"><a name="_Hlk485215776"></a><i>February 23,<br />
2017</i></p>
<h2 style="text-align: center;" align="center"><a name="_Hlk485215738"></a>What&#8217;s New in Release &#8216;10.8&#8217;</h2>
<h3><a name="_Hlk485215806"></a>Bug Fixes</h3>
<p>·         Support for new 4 Channel Piezo adapters</p>
<p>·         Support for The Hub integration, still requires patch to enable</p>
<p style="text-align: right;" align="right"><i>November 16, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Support for 6mm Strain Gage sensors</p>
<p>·         Fixed bug where initial offset was always be set to zero on strain gage sensors</p>
<p style="text-align: right;" align="right"><i>October 10, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Can assign IA1 modules on Machine setup for coolant flow and temperature</p>
<p>·         When overwriting template in cycle graph the dialog would not close automatically</p>
<p>·         Audit log was no longer updating because the log file name was changed</p>
<p>·         Various translation fixes</p>
<p style="text-align: right;" align="right"><i>September 2, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         The Balance Viewer in the Cycle Graph did not show any data in other languages</p>
<p>·         You can now see the date that a template was saved when selecting a template in the Cycle Graph</p>
<p style="text-align: right;" align="right"><i>August 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<p>·         A user can now assign multiple flow meters in<br />
the machine setup and input an id for each sensor</p>
<p style="text-align: right;" align="right"><i>July 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed &#8216;Process Setup&#8217; disappearance issue.</p>
<p style="text-align: right;" align="right"><i>June 6, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed regression of not being able to assign multi channel piezo adapters with missing plate id</p>
<p>·         Fixed bug with V-&gt;P where changes would be reverted if you changed a value by more than 10%</p>
<p>·         Fixed bug where if you started a job with an unassigned sensor it would have incorrect default values set when you configured it later</p>
<p>·         Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries</p>
<p>·         It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still path to get both to show</p>
<p>·         Fixed bug with analog inputs where if they are converted from v9 setup they would have a full scale of 0</p>
<p style="text-align: right;" align="right"><i>Apr 11, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Set Screw Bottom is no longer skipped when starting a job after a reboot</p>
<p>·         Fixed the Job Started Output so that the module channel activates when a job is started</p>
<p>·         Removed the annotator and replaced it with a cycle values display on the cycle graph</p>
<p>·         Cavity Fill Time Balance Percentage added as a summary variable.</p>
<p>·         Cushion can be calculated with analog input modules</p>
<p>·         V-P layout improved for better visibility of the cycle graph window</p>
<p>·         Mini Mega MCSG Adapter Support</p>
<p>·         i icon missing for Sensors setup</p>
<p>·         Analog input sensors used for stroke now allow 0 and 10 V to be swapped between screw bottom and full shot</p>
<p>·         Balance Viewer Sensor Name display as cavity names instead of aliases</p>
<p>·         Corrupt file and directory detection and handing</p>
<p style="text-align: right;" align="right"><i>Dec 3, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of temperature</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·         Fixed bug introduced in 10.7.1 that would not show sensors on the Mold Outputs configuration page </span></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed bug where you could assign MCSG sensor when a plate was not attached which would cause sensor location to block when starting a job</p>
<p>·         Fixed bug where sensors would not correctly populate the unused sensor list</p>
<p>·         Fixed bug where mega multi channel sensor may not show up as connected if connected after you start<br />
editing the mold</p>
<p>·         Changed the way the Multi channel adapter display the plate that is attached, it now shows both the adapter serial number and plate id, when a sensor is configured in a location is only shows the plate<br />
id</p>
<p>·         Fixed that you could not show summary variables or add alarms for Coolant Flow Temperature sensors</p>
<p>·         Added support for new mega SG/LX8-S-ID</p>
<p style="text-align: right;" align="right"><i>Aug 6, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Cycle Graph pop-up annotator replaced by fixed location cycle values and balance viewer.</p>
<p>·         Excessive Rejects clear function now has it&#8217;s own security item called &#8220;Excessive Rejects&#8221;; was previously bundled in with the process security.</p>
<p style="text-align: right;" align="right"><i>July 8, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable</p>
<p>·         Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access</p>
<p>·         Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing</p>
<p>·         On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed</p>
<p>·         On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works</p>
<p>·         On the cycle graph, template control windows should open in consistent positions</p>
<p>·         Long text should no longer be cutoff on the Alarm Settings page</p>
<p>·         Long text should no longer be cutoff on the Stability Match pages</p>
<p>·         Long text should no longer be cutoff on the Cycle Alarm indicators</p>
<p>·         Long text should no longer be cutoff on the Alarm Count page</p>
<p>·         Values on Cycle Alarm indicators are now displayed in current units and the units are shown</p>
<p>·         On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the<br />
mold setup. This would lead to sensors not being configured correctly if the setup was then saved. It will now have the right settings.</p>
<p>·         When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was confusing. It no longer does this.</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and Changes</h3>
<p>·         Support for Peak Ejector Force Optional Tool.</p>
<p>·         Added support for dual analog flow/temperature IA2-M-FT.</p>
<h3>Bug Fixes</h3>
<p>·         Fix for Valve Gate always defaulting to &#8220;Open Gate&#8221;.</p>
<p>·         Fix for job started output, now on when the job is running and off when the job is started.</p>
<p>·         Template Match Values are now displayed.</p>
<p>·         Home menu now disappears when focus is lost.</p>
<p>·         Disallows testing Job Started, Job Down and Job Running outputs while the job is running.</p>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>eDART Software Version: 10.8.3</title>
		<link>https://it.rjginc.com/product/edart-software-version-10-8-3/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Fri, 20 Aug 2021 12:59:09 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=234244</guid>

					<description><![CDATA[<div class="modal-header">
<h3 id="note-modal-title">Important Note</h3>
</div>
<div class="modal-body">
<div id="note-content">

The <em>eDART</em> must be at 10.7 or above before this update can be applied.

The EDM Upgrade 2.6.1 is REQUIRED in order for the <em>eDART</em>s to share security files and default files automatically. Please read how the new automatic copy will work with this upgrade. <a href="https://rjginc.com/wp-content/uploads/2018/10/File_Version_Control.pdf">The attached file is the read me file.</a>

</div>
</div>]]></description>
										<content:encoded><![CDATA[<div>
<p>This document covers only the series v10 releases.</p>
<p style="text-align: right;" align="right"><i>August 3, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed an issue with the Raw Data Viewer’s Port<br />
Diagnostics reporting negative values on devices which contained a serial number greater than 20******** [2020-year date].<i></i></p>
<p style="text-align: right;" align="right"><i>June 10, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Improved performance when selecting a Machine,<br />
Mold or Setup when there are a large number of configurations in the pick list.<i></i></p>
<p style="text-align: right;" align="right"><i>June 14, 2017</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be interrupted. When system restored communication, some sensors would be missing.</p>
<p style="text-align: right;" align="right"><a name="_Hlk485215776"></a><i>February 23, 2017</i></p>
<h2 style="text-align: center;" align="center"><a name="_Hlk485215738"></a>What&#8217;s New in Release &#8216;10.8&#8217;</h2>
<h3><a name="_Hlk485215806"></a>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Support for new 4 Channel Piezo adapters</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Support for The Hub integration, still requires<br />
patch to enable</p>
<p style="text-align: right;" align="right"><i>November 16, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Support for 6mm Strain Gage sensors</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug where initial offset was always be set to zero on strain gage sensors</p>
<p style="text-align: right;" align="right"><i>October 10, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Can assign IA1 modules on Machine setup for coolant<br />
flow and temperature</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>When overwriting template in cycle graph the<br />
dialog would not close automatically</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Audit log was no longer updating because the log<br />
file name was changed</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Various translation fixes</p>
<p style="text-align: right;" align="right"><i>September 2, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>The Balance Viewer in the Cycle Graph did not<br />
show any data in other languages</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>You can now see the date that a template was<br />
saved when selecting a template in the Cycle Graph</p>
<p style="text-align: right;" align="right"><i>August 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>A user can now assign multiple flow meters in<br />
the machine setup and input an id for each sensor</p>
<p style="text-align: right;" align="right"><i>July 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed &#8216;Process Setup&#8217; disappearance issue.</p>
<p style="text-align: right;" align="right"><i>June 6, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed regression of not being able to assign multi channel piezo adapters with missing plate id</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug with V-&gt;P where changes would be<br />
reverted if you changed a value by more than 10%</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug where if you started a job with an<br />
unassigned sensor it would have incorrect default values set when you<br />
configured it later</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still path to get both to show</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug with analog inputs where if they are<br />
converted from v9 setup they would have a full scale of 0</p>
<p style="text-align: right;" align="right"><i>Apr 11, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Set Screw Bottom is no longer skipped when starting a job after a reboot</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed the Job Started Output so that the module channel activates when a job is started</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Removed the annotator and replaced it with a cycle values display on the cycle graph</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Cavity Fill Time Balance Percentage added as a summary variable.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Cushion can be calculated with analog input modules</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>V-P layout improved for better visibility of the cycle graph window</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Mini Mega MCSG Adapter Support</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>i icon missing for Sensors setup</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Analog input sensors used for stroke now allow 0 and 10 V to be swapped between screw bottom and full shot</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Balance Viewer Sensor Name display as cavity names instead of aliases</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Corrupt file and directory detection and handing</p>
<p style="text-align: right;" align="right"><i>Dec 3, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of temperature</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Fixed bug introduced in 10.7.1 that would not show sensors on the Mold Outputs configuration page</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed bug where you could assign MCSG sensor when a plate was not attached which would cause sensor location to block when starting a job</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed bug where sensors would not correctly<br />
populate the unused sensor list</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed bug where mega multi-channel sensor may not show up as connected if connected after you start editing the mold</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Changed the way the Multi channel adapter display the plate that is attached, it now shows both the adapter serial number and plate id, when a sensor is configured in a location is only shows the plate<br />
id</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fixed that you could not show summary variables or add alarms for Coolant Flow Temperature sensors</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Added support for new mega SG/LX8-S-ID</p>
<p style="text-align: right;" align="right"><i>Aug 6, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Cycle Graph pop-up annotator replaced by fixed location cycle values and balance viewer.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Excessive Rejects clear function now has it&#8217;s own security item called &#8220;Excessive Rejects&#8221;; was previously bundled in with the process security.</p>
<p style="text-align: right;" align="right"><i>July 8, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>On the cycle graph, template control windows should open in consistent positions</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Long text should no longer be cutoff on the Alarm Settings page</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Long text should no longer be cutoff on the Stability Match pages</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Long text should no longer be cutoff on the Cycle Alarm indicators</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Long text should no longer be cutoff on the Alarm Count page</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Values on Cycle Alarm indicators are now displayed in current units and the units are shown</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>On the Diagnostic page sensor out of calibration<br />
errors now don&#8217;t cause sensors to show a warning symbol</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the mold setup. This would lead to sensors not being configured correctly if the setup was then saved. It will now have the right settings.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was confusing. It no longer does this.</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and Changes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Support for Peak Ejector Force Optional Tool.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Added support for dual analog flow/temperature IA2-M-FT.</p>
<h3>Bug Fixes</h3>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fix for Valve Gate always defaulting to &#8220;Open Gate&#8221;.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Fix for job started output, now on when the job is running and off when the job is started.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Template Match Values are now displayed.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">        </span></span>Home menu now disappears when focus is lost.</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·<span style="font: 7.0pt 'Times New Roman';">         </span></span>Disallows testing Job Started, Job Down and Job Running outputs while the job is running.</p>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>eDART Software Version: 10.8.1</title>
		<link>https://it.rjginc.com/product/edart-software-version-10-8-1/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 02 Oct 2018 12:40:04 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=56732</guid>

					<description><![CDATA[<div class="modal-header">
<h3 id="note-modal-title">Important Note</h3>
</div>
<div class="modal-body">
<div id="note-content">

The <em>eDART</em> must be at 10.7 or above before this update can be applied.

The EDM Upgrade 2.6.1 is REQUIRED in order for the <em>eDART</em>s to share security files and default files automatically. Please read how the new automatic copy will work with this upgrade. <a href="https://rjginc.com/wp-content/uploads/2018/10/File_Version_Control.pdf">The attached file is the read me file.</a>

</div>
</div>]]></description>
										<content:encoded><![CDATA[<p>This document covers only the series v10 releases.</p><p><i>June 14, 2017</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be interrupted. When system restored communication, some sensors would be missing.</li>
</ul><h2>What&#8217;s New in Release &#8216;10.8&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Support for new 4 Channel Piezo adapters</li>
<li>Support for The Hub integration, still requires patch to enable</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Support for 6mm Strain Gage sensors</li>
<li>Fixed bug where initial offset was always be set to zero on strain gage sensors</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Can assign IA1 modules on Machine setup for coolant flow and temperature</li>
<li>When overwriting template in cycle graph the dialog would not close automatically</li>
<li>Audit log was no longer updating because the log file name was changed</li>
<li>Various translation fixes</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>The Balance Viewer in the Cycle Graph did not show any data in other languages</li>
<li>You can now see the date that a template was saved when selecting a template in the Cycle Graph</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<ul>
<li>A user can now assign multiple flow meters in the machine setup and input an id for each sensor</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed &#8216;Process Setup&#8217; disappearance issue.</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed regression of not being able to assign multi channel piezo adapters with missing plate id</li>
<li>Fixed bug with V-&gt;P where changes would be reverted if you changed a value by more than 10%</li>
<li>Fixed bug where if you started a job with an unassigned sensor it would have incorrect default values set when you configured it later</li>
<li>Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries</li>
<li>It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still path to get both to show</li>
<li>Fixed bug with analog inputs where if they are converted from v9 setup they would have a full scale of 0</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Set Screw Bottom is no longer skipped when starting a job after a reboot</li>
<li>Fixed the Job Started Output so that the module channel activates when a job is started</li>
<li>Removed the annotator and replaced it with a cycle values display on the cycle graph</li>
<li>Cavity Fill Time Balance Percentage added as a summary variable.</li>
<li>Cushion can be calculated with analog input modules</li>
<li>V-P layout improved for better visibility of the cycle graph window</li>
<li>Mini Mega MCSG Adapter Support</li>
<li><q>i</q> icon missing for Sensors setup</li>
<li>Analog input sensors used for stroke now allow 0 and 10 V to be swapped between screw bottom and full shot</li>
<li>Balance Viewer Sensor Name display as cavity names instead of aliases</li>
<li>Corrupt file and directory detection and handing</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of temperature</li>
<li>Fixed bug introduced in 10.7.1 that would not show sensors on the Mold Outputs configuration page</li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug where you could assign MCSG sensor when a plate was not attached which would cause sensor location to block when starting a job</li>
<li>Fixed bug where sensors would not correctly populate the unused sensor list</li>
<li>Fixed bug where mega multi channel sensor may not show up as connected if connected after you start editing the mold</li>
<li>Changed the way the Multi channel adapter display the plate that is attached, it now shows both the adapter serial number and plate id, when a sensor is configured in a location is only shows the plate id</li>
<li>Fixed that you could not show summary variables or add alarms for Coolant Flow Temperature sensors</li>
<li>Added support for new mega SG/LX8-S-ID</li>
</ul><h2>What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Cycle Graph pop-up annotator replaced by fixed location cycle values and balance viewer.</li>
<li>Excessive Rejects clear function now has it&#8217;s own security item called &#8220;Excessive Rejects&#8221;; was previously bundled in with the process security.</li>
</ul><h2>What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable</li>
<li>Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access</li>
<li>Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing</li>
<li>On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed</li>
<li>On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works</li>
<li>On the cycle graph, template control windows should open in consistent positions</li>
<li>Long text should no longer be cutoff on the Alarm Settings page</li>
<li>Long text should no longer be cutoff on the Stability Match pages</li>
<li>Long text should no longer be cutoff on the Cycle Alarm indicators</li>
<li>Long text should no longer be cutoff on the Alarm Count page</li>
<li>Values on Cycle Alarm indicators are now displayed in current units and the units are shown</li>
<li>On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol</li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the mold setup. This would lead to sensors not being configured correctly if the setup was then saved. It will now have the right settings.</li>
<li>When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was confusing. It no longer does this.</li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and Changes</h3>
<ul>
<li>Support for Peak Ejector Force Optional Tool.</li>
<li>Added support for dual analog flow/temperature IA2-M-FT.</li>
</ul>
<h3>Bug Fixes</h3>
<ul>
<li>Fix for Valve Gate always defaulting to &#8220;Open Gate&#8221;.</li>
<li>Fix for job started output, now on when the job is running and off when the job is started.</li>
<li>Template Match Values are now displayed.</li>
<li>Home menu now disappears when focus is lost.</li>
<li>Disallows testing Job Started, Job Down and Job Running outputs while the job is running.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>eDART Software Version: 10.7</title>
		<link>https://it.rjginc.com/product/edart-software-version-10-7/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Sun, 02 Sep 2018 13:14:23 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=56768</guid>

					<description><![CDATA[<div class="modal-header">
<h3 id="note-modal-title">Important Note</h3>
</div>
<div class="modal-body">
<div id="note-content">
<p class="text-error">The <em>eDART </em>must be at 10.3 or above before this update can be applied.</p>
The EDM Upgrade 2.6.1 is REQUIRED in order for the <em>eDART</em>s to share security files and default files automatically. Please read how the new automatic copy will work with this upgrade. <a href="https://rjginc.com/wp-content/uploads/2018/10/File_Version_Control.pdf">The attached file is the read me file.</a>

</div>
</div>]]></description>
										<content:encoded><![CDATA[<p><em>Aug 6, 2015</em></p>
<h2>What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Cycle Graph pop-up annotator replaced by fixed location cycle values and balance viewer.</li>
<li>Excessive Rejects clear function now has it&#8217;s own security item called &#8220;Excessive Rejects&#8221;; was previously bundled in with the process security.</li>
</ul>
<p><em>July 8, 2015</em></p>
<h2>What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable</li>
<li>Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access</li>
<li>Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing</li>
<li>On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed</li>
<li>On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works</li>
<li>On the cycle graph, template control windows should open in consistent positions</li>
<li>Long text should no longer be cutoff on the Alarm Settings page</li>
<li>Long text should no longer be cutoff on the Stability Match pages</li>
<li>Long text should no longer be cutoff on the Cycle Alarm indicators</li>
<li>Long text should no longer be cutoff on the Alarm Count page</li>
<li>Values on Cycle Alarm indicators are now displayed in current units and the units are shown</li>
<li>On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol</li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the mold setup. This would lead to sensors not being configured correctly if the setup was then saved. It will now have the right settings.</li>
<li>When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was confusing. It no longer does this.</li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and Changes</h3>
<ul>
<li>Support for Peak Ejector Force Optional Tool.</li>
<li>Added support for dual analog flow/temperature IA2-M-FT.</li>
</ul>
<h3>Bug Fixes</h3>
<ul>
<li>Fix for Valve Gate always defaulting to &#8220;Open Gate&#8221;.</li>
<li>Fix for job started output, now on when the job is running and off when the job is started.</li>
<li>Template Match Values are now displayed.</li>
<li>Home menu now disappears when focus is lost.</li>
<li>Disallows testing Job Started, Job Down and Job Running outputs while the job is running.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>