<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Modules | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-category/auxiliary-hardware-it/modules-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Fri, 24 Apr 2026 15:44:38 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.7</generator>

<image>
	<url>https://it.rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>Modules | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OA1-M-V</title>
		<link>https://it.rjginc.com/product/oa1-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/oa1-m-5/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="3">OA1-M-V
1 Analog Output</td>
<td>0-10 VDC</td>
</tr>
<tr>
<td>Accuracy ±1%</td>
</tr>
<tr>
<td>Electrically Isolated Input</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Analog Output Module  &#8211; Shielded</p>
<p>This isolated, analog output module can be used to interface with any sensor, or input, that accepts a 0-10V DC signal, like plastic and hydraulic pressure input cards. It can also be used as an external machine transfer.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and the <em>eDART</em><sup>®</sup> System. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OR2-M</title>
		<link>https://it.rjginc.com/product/or2-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/or2-m-5/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="2">OR2-M
2 Relay Outputs</td>
<td>Contact Rating 1A 30 VDC</td>
</tr>
<tr>
<td>Fused Dry Contacts</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Dual Relay Output Module  &#8211; Shielded</p>
<p>The dual contact closure output module is designed to be used with the <em>eDART</em><sup>®</sup> System. The module&#8217;s two dry contact outputs can also be configured to implement part containment or transfer a molding machine.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules as well as the <em>eDART</em> System. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Easy-to-read status LEDs</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VM Flowmeter e modulo di interfaccia</title>
		<link>https://it.rjginc.com/product/flowmeter/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 18:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/vm-4-b-40-b-5/</guid>

					<description><![CDATA[<table style="border-collapse: collapse; text-align: center;" border="0" width="100%" cellpadding="5">
<tbody>
<tr>
<td colspan="5">
<h4><strong>Model Variations by Thread Sizes</strong></h4>
</td>
</tr>
<tr>
<td><strong>VM3</strong></td>
<td><strong>VM4</strong></td>
<td><strong>VM6</strong></td>
<td><strong>VM8</strong></td>
<td><strong>VM12</strong></td>
</tr>
<tr>
<td>3/8"</td>
<td>1/2"</td>
<td>3/4"</td>
<td>1"</td>
<td>1.5"</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="text-align: left;">
<td colspan="5"><strong>Other variations to choose the right fit:</strong>
<ul>
 	<li>Thread Type</li>
 	<li>Flow Meter Connection</li>
 	<li>Water Flow Selection</li>
 	<li>Display (UI Interface) Option</li>
</ul>
</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Smartflow 1/2&#8243; NPT 2-40 LPM</p>
<p>This device is a simple flow meter to measure either the input to the mold or to individual circuits. This can also be done with water temperature. When interfaced with the <em>eDART</em><sup>® </sup>System, users can access and use data such as: excessive reject control, summary variables, template values, and summary and cycle values.</p>
<p><strong>What you can do:</strong></p>
<ul>
<li>Determine if the water temperature control unit is delivering the correct temperature needed to make good parts</li>
<li>Reject parts if the flow or temperature doesn&#8217;t meet your set requirements to make a good part</li>
<li>Create a template of the flow or water temperature</li>
<li>Overlay your GPM or temperature curves on the cycle graph</li>
<li>Set alarms around peak values of the flow or temperature of the coolant</li>
<li>Set excessive rejects to stop the machine if the flow or temperature of the coolant rejects parts more than your set thresholds</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DIN/LX-M</title>
		<link>https://it.rjginc.com/product/din-lx-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/din-lx-m-5/</guid>

					<description><![CDATA[Lynx™ Communication Adapter  &#8211; Shielded The DIN/LX-M is a Lynx to DIN rail communications module that acts as an interface between standard Lynx cables and Lynx DIN rail mounted modules when not using an ID7-M-SEQ. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. It is designed to be [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Communication Adapter  &#8211; Shielded</p>
<p>The DIN/LX-M is a Lynx to DIN rail communications module that acts as an interface between standard Lynx cables and Lynx DIN rail mounted modules when not using an ID7-M-SEQ. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. It is designed to be used with the <em>eDART</em><sup>®</sup> System and to be mounted on standard 35 mm DIN rails often found in machine panels.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IA1-M-V</title>
		<link>https://it.rjginc.com/product/ia1-m-v/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/ia1-m-v-5/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td style="width: 50%;" width="50%">All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="3">IA1-M-V
1 Analog Input</td>
<td>0-10 VDC</td>
</tr>
<tr>
<td>Accuracy ±1%</td>
</tr>
<tr>
<td>Electrically Isolated Input</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Analog Input Module &#8211; Shielded</p>
<p>This module accepts 0-10V DC signals from analog sensors and equipment in order to integrate them into the <em>eDART</em><sup>®</sup> System. This din-rail module is shielded to ensure high quality data even in rugged molding environments. Examples of sensors that can be used with this module include: electric machine injection pressure, temperature, dew point, and plastic pressure.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and the eDART System. Each machine panel installation of one or more DIN rail module requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ID/LX1-S</title>
		<link>https://it.rjginc.com/product/id-lx1-s/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/id-lx1-s-5/</guid>

					<description><![CDATA[IDENTIFICATORE STAMPO LYNX]]></description>
										<content:encoded><![CDATA[<p>IDENTIFICATORE STAMPO LYNX</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ID7-M-SEQ</title>
		<link>https://it.rjginc.com/product/id7-m-seq/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/id7-m-seq-5/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="2">ID7-M-SEQ
7 Sequence Inputs</td>
<td>Maximum Input Voltage 36 VDC, Minimum Trigger-On Voltage 18 VDC</td>
</tr>
<tr>
<td>Electrically Isolated Inputs</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx Sequence Module  &#8211; Shielded</p>
<p>Once wired to the molding machine, this module provides the system with machine timing sequences, including injection forward, screw run, mold closed, first stage, and mold opening. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. .</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity in eletrically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Easy-to-read status LEDs</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		